PM Coupler

1060nm Cladding Power Stripper

Cladding Power Stripper for use in high-power fiber lasers and amplifiers need to be able to handle substantial optical powers. It needs to be ensured that these powers are absorbed in a sufficiently widespread region, and that the generated heat can be removed safely, without damaging the mode stripper or any surrounding parts.

 

In fiber laser, the pump energy is absorbed along with doped fiber, transforming into signal energy, but pump cannot be absorbed completely, the residual part in outer cladding is no need, even dangerous for downstream components, with CPS can effectively "strip off" residual pump and signal which transmit back in clad, meantime keep the amplified signal unaffected.

Name:
1060nm Cladding Power Stripper
Price:As low as

  

Features

Applications

High power handling

Low Insertion loss

Cost Effective

Fiber lasers

 

Performance Specifications

Parameters

Values

Center Wavelength(nm)

1060

Operating Wavelength-Pumps (nm)

800~1200

Cladding attenuation(min)(dB)

20

Max. Insertion Loss (at 25) (dB)

0.30

Min. Polarization Extinction Ratio (dB)

18(For PM Fiber)

Cladding Power Handling(W)

10, 20, 30

Fiber Type In/Out

10/125, 15/130, 20/125 DCF or Specify

Pigtail Length(m)

1.0 or other

Operation Temperature()

0 ~ +50

Storage Temperature Range()

-20 ~ +75

* Above specification are for device without connector, and may change without notice.

General Configuration for CPS:

Working Wavelength(nm)

Input/ouput Fiber

Signal IL

Min.Stripping Efficiency

Max.Power Handling

1020~1080

6/125 DC

0.3dB

20dB

50W

1530~1570

8/125 DC

0.3dB

20dB

50W

1020~1080

10/125 DC

0.3dB

20dB

50W

1020~1080

12/125 DC

0.3dB

20dB

50W

1020~1080

15/125 DC

0.3dB

20dB

50W

1020~1080

20/125 DC

0.3dB

20dB

10W

1020~1080

20/200 DC

0.3dB

20dB

50W

1020~1080

25/250 DC

0.3dB

20dB

200W

1530~1570

25/300 DC

0.3dB

17dB

50W

1020~1080

30/250 DC

0.3dB

20dB

300W

1020~1080

20/400 DC

0.3dB

17dB

500W

1020~1080

PM6/125 DC

0.3dB/ER>18dB

20dB

50W

1020~1080

PM10/125 DC

0.3dB/ER>18dB

20dB

50W

1020~1080

PM15/125 DC

0.3dB/ER>18dB

20dB

50W

1020~1080

PM20/125 DC

0.3dB/ER>18dB

20dB

50W

1020~1080

PM20/200 DC

0.3dB/ER>18dB

20dB

100W

1020~1080

PM25/250 DC

0.3dB/ER>18dB

20dB

300W

1020~1080

PM30/250 DC

0.3dB/ER>18dB

20dB

300W

1020~1080

PM20/400 DC

0.3dB/ER>18dB

17dB

500W

Remark:

1.Other configuration can be customized.We can build CPS on every double clad fiber,

2.For handling power100W and some samll core fiber CPS, will need water cooling.

3.All CPS default with bare fiber,0.8m length of pigtail, please contact us for special request.

 

Package Information

Package Type

T1

T2

T3

T4

T5

Dimensions (mm)

Ф3x54

65×12×7.5

70×12×8

65×12×7.5

65×12×7.5

Positioning hole(mm)

/

7.0×54

7.0×54

8.4×54

12×54

 

 

Order information

CPS-----

wavelength

Cladding Power Handling

Fiber Type

Fiber Jacket on Input & Output

Fiber Length

64:1064nm

XX:Other

10:10W

20:20W

30:30W

XX:Other

XXX(fiber name)

B:Bare Fiber

L:900um Loose Cable

C:3MM Loose Cables

X: Others

10:1.0m

XX:Other